UL1672 scelgono il cavo inguainato PVC isolato PVC del conduttore per collegamenti interni
UL1672 Single Conductor with Extruded Insulation,105℃, 300V, VW-1,60 ℃ or 80 ℃ Oil Construction Conductor : Solid or Stranded Insulation: PVC Standards International: UL758 , UL1581, UL2556 RoHS,REACH Compliant, Technical data Rated voltage:300V Rated Temperature: -40~105℃ Flame: VW-1, FT1, FT2 Oil ...
UL10455 scelgono i cavi isolati PVC del conduttore per i collegamenti interni dell'attrezzatura elettronica
UL10455 Single conductor using extruded non-integral jacket, 90 ℃, 600 V VW-1, 60 ℃ or 80 ℃ Oil Construction Conductor : Solid or Stranded Insulation: PVC Jacket: PVC Standards International: UL758 , UL1581, UL2556 RoHS,REACH Compliant, Technical data Rated voltage:600 V Rated Temperature:90℃ Flame: ...
UL10603 FRPE isolati scelgono il cavo del conduttore, AWG flessibile del cavo elettrico 26 - AWG 9
UL10603 Single Conductor with extruded FRPE insulation, 80 ℃, 600 V VW-1 Construction Conductor : Solid or Stranded Insulation: FRPE Standards International: UL758 , UL1581, UL2556 RoHS,REACH Compliant, Technical data Rated voltage: 600 V Rated Temperature: 80℃ Flame: VW-1, FT1, FT2 Voltage ...
UL3321 scelgono il cavo flessibile del cavo del cavo del conduttore con l'isolamento espulso di XLPE
UL3321 Single Conductor with extruded XLPE insulation, 150 ℃, 600 V or 750V VW-1 Construction Conductor : Solid or Stranded Insulation: XLPE Standards International: UL758 , UL1581, UL2556 RoHS,REACH Compliant, Technical data Rated voltage: 600 V OR 750V Rated Temperature: 150℃ Flame: VW-1, FT1, FT2 ...
Cavo del conduttore dell'isolamento di UL3820 XLPE il singolo, flette l'AWG del cavo elettrico 30 - Kcmil 2000
UL3820 Single Conductor with extruded XLPE insulation, 125℃, 1000 V VW-1 Construction Conductor : Solid or Stranded Insulation: XLPE Standards International: UL758 , UL1581, UL2556 RoHS,REACH Compliant, Technical data Rated voltage: 1000 V Rated Temperature: 125℃ Flame: VW-1, FT1, FT2 Voltage ...
UL1483 scelgono il cavo del conduttore con conduttore di rame in scatola/nudo non integrato del rivestimento
UL1483 Single conductor using extruded non-integral jacket, 105 ℃, 600 V VW-1, 60 ℃ or 80 ℃ Oil Construction Conductor : Solid or Stranded Insulation: PVC Jacket: PVC Standards International: UL758 , UL1581, UL2556 RoHS,REACH Compliant, Technical data Rated voltage:600 V Rated Temperature:105℃ Flame...
40 AWG - singolo cavo del conduttore di 10 AWG con l'isolamento espulso UL10602 di FRPE
UL10602 Single Conductor with extruded FRPE insulation, 80 ℃, 300 V VW-1 Construction Conductor : Solid or Stranded Insulation: FRPE Standards International: UL758 , UL1581, UL2556 RoHS,REACH Compliant, Technical data Rated voltage: 300 V Rated Temperature: 80℃ Flame: VW-1, FT1, FT2 Voltage ...
Singolo cavo elettrico del conduttore UL10863 con l'alogeno espulso dell'isolamento di FRPE liberamente
UL10863 Single Conductor with extruded FRPE insulation, 80 ℃, 1000 V VW-1 Construction Conductor : Solid or Stranded Insulation: FRPE Standards International: UL758 , UL1581, UL2556 RoHS,REACH Compliant, Technical data Rated voltage: 1000 V Rated Temperature: 80℃ Flame: VW-1, FT1, FT2 Voltage ...
UL10198 isolati PVC scelgono il cavo del conduttore, cavo flessibile termoresistente
UL10198 Single Conductor with Extruded Insulation,105℃, 300V, VW-1,60 ℃ or 80 ℃ Oil Construction Conductor : Solid or Stranded Insulation: PVC Standards International: UL758 , UL1581, UL2556 RoHS,REACH Compliant, Technical data Rated voltage:300V Rated Temperature: -40~105℃ Flame: VW-1, FT1, FT2 Oil ...